Tekequip.com

Rigol DSA1030-TG3 9kHz to 3GHz Spectrum Analyser with Tracking Generator

€2,895.00

€2,895.00

£2,588.90

£2,588.90

Without VAT

In stock ready to ship

Free shipping within EU

Quick Overview

- 9kHz - 3GHz Frequency Range
- 138dBm Displayed Average Noise Level
- 80dBc/Hz @10kHz Phase Noise (typ.)
- Overall Amplitude accuracy < 1.0dB
- 10Hz Minimum Resolution Bandwidth
- 3GHz Tracking Generator
- Built-in battery -3h. continuous operation (opt.)
- Breadth of measurement func. & auto.settings
- 8.5inch widescreen colour display with clear,vivid
- Interface LAN/USB host/dev.,VGA,GPIB (opt.)
- Compact design, only 6.20Kg
 
  • The ability to measure smaller signals. Smaller bandwidth setting for reducing DANL
  • The ability to distinguish between small signals by frequency
  • High precision amplitude readings
  • High measurement speed. Improved bandwidth precision and selectivity of the filter to minimize scanning time
  • Breads of measurement functions and automatic settings
  • Unique widescreen 8.5" TFT LCD display with 800×480 high resolution and fine spectral lines for displaying large data sets
  • Various interface options: LAN/USB host, USB device, VGA or GPIB (option)
  • Built-in lithium battery. 3 hours continuous operation
  • Compact design with a weight of only 6.2 kg without battery pack

 

Rigol DSA1030A-TG3 Spectrum Analyzer Features



    * 8.5 inch widescreen LCD display with 800×480 resolution
    * Clear, vivid graphical interface with various options: LAN/USB host, USB device, VGA or GPIB
    * Compact and rugged design, which makes the analyzer ideal for many portable and field applications. Spot tests are easier than ever with this small, lightweight analyzer. Despite the small size, the analyzer has a built-in 3 hour lithium battery, easy carry system, extra storage space (non-volatile memory) onboard and the ability to store data directly to a USB flash device
    * Various measurement functions:
          o Time domain power
          o Channel power
          o Adjacent-channel power
          o Occupied bandwidth
          o Carrier to noise ratio
          o Harmonic distortion
          o Intermodulation distortion
          o Frequency count
          o N dB
          o Noise marker and so on.
      Software displays waterfall curves to expand the measurement capabilities to even more applications. 

Advanced Measurement Functions
 
Clear Display
 
 
Advanced Measurement Capability

 

Auto Functions

 

Automatic setting and functions.

Auto tune, auto range, auto scale, auto couple enable the analyzer to acquire signals and match parameters automatically, instead of the manual process used by a traditional analyzer.
The user and factory settings under the preset function help you to quickly and easily recall previous measurement settings.

Digital IF design. Benefits:

    * Ability to measure smaller signals measurements. IF filter enables smaller bandwidth settings and greatly reduces the displayed average noise level
    * Ability to make out signals with frequency difference of only 10 Hz
    * High precision amplitude readings. This technology almost completely eliminates errors generated by filter switching, reference level uncertainty, and scale distortion, as well as errors produced in the process of switching between logarithmic and linear display of amplitude when using a traditional analog design
    * Higher reliability. IF technology greatly reduces the complexity of the hardware, the system instability caused by channel aging, and the temperature sensitivity, which can contribute to parts failure
    * High measurement speed. Improved bandwidth precision, filter selectivity and minimized scanning time
 

Frequency

Frequency
Frequency Range9kHz to 3GHz
Internal Frequency Reference
Reference frequency10 MHz
Aging Rate<3 ppm/year
Temperature Drift20 ºC to 30 ºC<3 ppm
Frequency Readout Accuracy
Marker Resolutionspan / (sweep points-1)
Marker Uncertainty± (frequency indication × frequency reference uncertainty +1%
× span +10% × resolution bandwidth + marker resolution)
Marker Frequency Counter
Resolution1 Hz, 10 Hz, 100 Hz, 1 kHz
Uncertainty± (frequency indication × frequency reference uncertainty  + counter resolution)
Frequency Span
Range0 Hz, 100 Hz to 3 GHz
Uncertainty± span / (sweep points-1)
SSB Phase Noise
Carrier Offset10 kHz<-88 dBc / Hz typ.
100 kHz<-100 dBc / Hz typ.
11 MHz<-110 dBc / Hz typ.
Bandwidths
Resolution Bandwidth (-3dB)10 Hz to 1 MHz, in 1-3-10 sequence
RBW Uncertainty< 5%, nominal
Resolution Filter Shape Factor (60 dB: 3dB)<5, nominal
Video Bandwidth (-3dB)10 Hz to 3 MHz, in 1-3-10 sequence

Amplitude

Measurement Range
RangeDANL to +30 dBm
Maximum Rated Input Level
Dc Voltage50 V
CW RF PowerRF attenuation ≥ 20 dB33 dBm (1W)
Max. Damage Level40 dBm (10W)
Displayed Average Noise Level (DANL)
0 dB RF attenuation, RBW=100Hz, VBW=10Hz, sample detector, trace average ≥ 50
DANL (Preamplifier Off)100 kHz to 10 MHz<-85 dBm - 3 f(MHz)dB, typ. -125 dBm
10 MHz to 2.5 GHz<-127 dBm - 3 × (f/MHz)dB, typ. -130 dBm
2.5 GHz to 3 GHz<-115dBm
DANL (Preamplifier Off)100 kHz to 10 MHz<-103 dBm - 3 f(MHz)dB, typ. -143 dBm
10 MHz to 2.5 GHz<-145 dBm + 3 ×(f/MHz)dB, typ. -148 dBm
2.5 GHz to 3 GHz<-133dBm
Level Display
Logarithmic Level Axis1 dB to 200 dB
Linear Level Axis0 to Reference Level
Number of Display PointsNormal601
Full Screen751
Number of Traces3 + math trace
Trace DetectorsNormal, Positive-peak, Negative-peak, Sample, RMS, Voltage Average
Trace FunctionsClear Write, Max Hold, Min Hold, Average, View, Blank
Units of Level AxisdBm, dBmV, dBµV, nV, µV, mV, V, nW, µW, mW, W
Frequency Response
10 dB RF attenuation, relative to 50 MHz, 20ºC to 30ºC
Frequency Response
(Preamplifier Off)
100 kHz to 3 GHz<0.7 dB
Frequency Response
(Preamplifier On)
1 MHz to 3 GHz<1.0 dB
Input Attenuation Switching Uncertainty
Setting Range0 to 50 dB, in 1 dB step
Switching Uncertaintyfc=50MHz, relative to 10 dB, 20ºC to 30ºC< (0.3 +0.01 × attenuator settings) dB
Absolute Amplitude Uncertainty
Uncertaintyfc=50 MHz, peak detector, preamplifier off,
10 dB RF attenuation, input signal = -10 dBm, 20ºC to 30ºC
± 0.4 dB
Reference Level
Range- 100 dBm to + 30 dBm, in 1 dB step
ResolutionLog Scale0.01 dB
Linear Scale4 digits
Uncertainty<0.1 dB, nominal
Level Measurement Uncertainty
Level Measurement Uncertainty95% confidence level, S/N > 20 dB, RBW=VBW=1kHz,
preamplifier off, 10 MHz < fc< 3 GHz, 20ºC to 30 ºC
<1.0 dB, nominal
RF Input VSWR
10 dB RF attenuation
VSWR100 kHz to 10 MHz<1.8
10 MHz to 2.5 GHz<1.5
2.5 GHz to 3 GHz<1.8
Intermodulation
Second Harmonic Intercept (SHI) +35 dBm
Third-order Intermodulation (TOI)fc > 30 MHz+7 dBm
Spurious Responses
Image Frequency <-60 dBc
Intermediate Frequency <-60 dBc
Spurious Responses, Inherent <-88 dBm, typ.
Spurious Responses, Othersreferenced to local oscillators,
referenced to A/D conversion,
referenced to subharmonic of first LO
referenced to harmonic of first LO
<-60 dBc
Input Related SpuriousMixer level: -30 dBm<-60 dBc, typ.

Sweep

Sweep Time Range100 Hz ≤ Span ≤3 GHz10 ms to 3000 s
Span = 020 µs to 3000 s
Sweep Time Uncertainty100 Hz ≤ Span ≤3 GHz5%, nominal
Span = 00.5%, nominal
Sweep Mode continuous, single

Trigger Function

Trigger SourceFree run, Video, External
External Trigger Level5 V TTL level

Tracking Generator

TG Output
Frequency Range 10 MHz to 3 GHz
Output Level - 20 dBm to 0 dBm, in 1 dB step
Output FlatnessReferenced to 50 MHz± 3 dB

Inputs and Outputs

RF Input
Impedance50Ω
ConnectorN female
TG Out
Impedance50Ω
ConnectorN female
Probe Power
Voltage / Current+15 V, <10% (150 mA)
-12.6 V, <10% (150 mA)
10 MHz REF In / 10 MHz REF Out / External Trigger In
ConnectorBNC female
10 MHz REF Amplitude0 dBm to 10 dBm
Trigger Voltage5 V TTL level
USB
USB HostConnectorB plug
ProtocolVersion 2.0
USB deviceConnectorA plug
ProtocolVersion 2.0
VGA
ConnectorVGA compatible, 15-pin mini D-SUB
Resolution800×600, 60 Hz

General Specifications

Display
TypeTFT LCD
Resolution800 480
Size8.5"
Colors65536
Printer Supported
ProtocolPictBridge
Remote Control
USB USB TMC
LAN Interface 10/100 Base-T, RJ-45
IEC/IEEE bus (GIB)with opt. USB-GPIBIEEE488.2
Mass Memory
Mass Memory Flash disc (internal)
USB Disc (not supplied)
Data Storage SpaceFlash disc (internal)2 Gbs
Power Supply
Input Voltage Range, AC100 V to 240 V, nominal
AC Supply Frequency45 Hz to 440 Hz
Input Voltage Range, DC10 V to 18 V, nominal
Power Consumptiontyp. 35 W, max 60 W with all options
Operation Time at DC Power Supplyabout 3 hours
Temperature
Operating Temperature Range5ºC to 40ºC
Storage Temperature Range-20ºC to 70ºC
Dimensions
W × H × D399 × 223 × 159 mm
15.7 × 8.78 × 6.26 inches
Weight
Without Battery Pack6,2 kg
13.7 lbs
With Battery Pack7.4 kg
16.3 lbs